GREE Livo R32 24,000 Btu/h class

GREE rates this single-zone wall system for 24,000 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
LIV24HP230V1R32AH
Outdoor unit
LIV24HP230V1R32AO

Cost and room performance

Equipment and ten years of electricity

$6,118.02

Listed equipment price
$3,053 single retailer
Ten years of electricity
$3,065.02
Annual electricity use
1,702.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $6,118.02
    44 / 100
  • Price per 1,000 Btu/h at 5°F $194.46
    54 / 100
  • Heat available at 5°F 15,700 Btu/h
    45 / 100
  • Electricity for 1 million Btu at 5°F 167.5 kWh
    0 / 100
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan N/A
    N/A
  • Indoor sound, highest fan N/A
    N/A
  • Electricity for 1 million Btu of cooling 52.6 kWh
    21 / 100
  • Electricity for 1 million Btu of heat 117.6 kWh
    13 / 100
  • Equipment price $3,053.00
    46 / 100
  • Heat retained at 5°F 70.1%
    12 / 100
  • Seasonal cooling efficiency 19 SEER2
    11 / 100
  • Earlier weighted value score 98.1 (size-class reference of 100)
    17 / 100

Electricity per million Btu

Cooling
52.6 kWh
Heating · Region IV rating
117.6 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$194.46
Heat available at 5°F
15,700 Btu/h
COP at 5°F
1.75
Electricity per million Btu at 5°F
167.5 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
N/A

A cooling-mode fan range is unavailable in the model documents.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$3,053
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the LIV24HP230V1R32AH and LIV24HP230V1R32AO, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • PTAC Direct
    $3,053

What an installation quote covers

The median equipment price in the 24,000 Btu/h class is $3,299 (15 of 15 systems priced).

Earlier price and efficiency score

Weighted score 98.1. Provisional · Based on one retailer. The reference for the 24,000 Btu/h class is 100.

Efficiency-only benchmark 91.5.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity24,000 Btu/h
Marketed size class24,000 Btu/h
Seasonal efficiency (SEER2)19 Btu/Wh
Efficiency at the rating point (EER2)11.9 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)8.5 Btu/Wh
Rated output at 47°F24,000 Btu/h
Rated output at 17°F19,200 Btu/h
Rated output at 5°F15,700 Btu/h
Sound levels
Indoor minimum · operating mode unspecified36 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings5.3%
Cooling input reduction at the EER2 test point-0.8%
Seasonal heating electricity savings-5.9%
Electricity savings with equal heating and cooling loads-2.2%
Heat at 5°F as a share of rated heat at 47°F70.1%
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) referenceN/A

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID4518149
AHRI reference214779349
Cold Climate designationYes
Rated cooling24,000 Btu/h
Heating at 47°F22,400 Btu/h
Heating at 17°F19,200 Btu/h
Heating at 5°F15,700 Btu/h
COP at 5°F1.75
SEER219 Btu/Wh
EER211.9 Btu/Wh
HSPF28.5 Btu/Wh
5°F output as a share of 47°F rated output70.09%

Reading the sources

The model sheet and the ENERGY STAR listing give different values. The catalog uses the equipment document for cooling capacity and efficiency.

MeasurementEquipment documentENERGY STAR
Rated heat at 47°F (Btu/h)24,00022,400

The manufacturer lists both component numbers together in its single-zone equipment submittal.

minisplitscout.com/systems/liv24hp230v1r32ah--liv24hp230v1r32ao/