How the rankings work
Start with the heating and cooling loads for the room. Use those to choose a size, then choose what to rank. The lowest equipment and electricity cost comes first in the default view. A small system can be inexpensive and still leave the room cold. How to match a heat pump to the room’s load
The catalog opens with the full list. Selecting a filter ranks all matching systems together. Equal displayed values share a place, so two systems tied for second are followed by fourth place. Dollars are compared to the cent and energy use to a tenth of a kWh. Systems without a comparable reading appear after the ranked systems and show N/A for that criterion. Catalog order and capacity order are browsing views, with a dash in the rank and score columns.
How to read the 0–100 score
The best measured result for your selected criterion earns 100 points. The worst earns 0. A result halfway between them earns 50. For example, if low-fan sound ranges from 20 to 30 dB(A), a unit rated at 22 dB(A) gets 80 points.
Score = 100 × (model value − worst value) ÷ (best value − worst value), rounded to the nearest whole point. Two systems can earn the same rounded score and still have different ranks. The measurement column shows the difference.
Filtering by brand or size changes which systems you see. Each score still uses the full catalog for the selected criterion. Changing your electricity rate or heating and cooling loads recalculates the ten-year cost scores. If all available readings are the same, you’ll see the measurement and N/A for the score. Scoring requires at least two distinct values.
Equipment and ten years of electricity
Add the equipment price to the cost of running every pair under the same loads. The starting example delivers 10 million Btu of heat and removes 10 million Btu of heat per year, at $0.18/kWh. Change the loads or the rate to match your project. These are example inputs. An energy model for the room can supply better ones.
- Electricity per million Btu
- Cooling = 1,000 ÷ SEER2. Heating = 1,000 ÷ HSPF2 (Region IV). Both results are in kWh.
- Annual kWh
- Cooling load × cooling kWh per million Btu + heating load × heating kWh per million Btu. Enter each annual load in millions of Btu.
- Ten-year estimate in dollars
- Equipment price + 10 × annual kWh × electricity rate.
The scenario holds the equipment, annual loads and electricity rate constant over ten years. Installation, maintenance, taxes, financing, replacement equipment and separate backup heat are outside it. Site conditions and controls affect the actual electricity bill. ENERGY STAR rating definitions · U.S. Department of Energy cost-comparison method
What a dollar buys in cold weather
Divide the equipment price by heating output at 5°F in thousands of Btu/h. A lower figure buys more output per dollar. Compare the output in Btu/h with the room’s heat loss at that same temperature. Each model sheet identifies an exact EPA match or a model-family match.
To compare electricity use during a cold spell, divide 1,000,000 by (3,412.142 × COP at 5°F). This gives the kWh required to deliver a million Btu at that test point. The seasonal heating row uses HSPF2 across a range of outdoor temperatures.
Light loads and bedroom noise
Look at the lowest steady heating output at 47°F and the lowest steady cooling output at 95°F. When the room needs less than the minimum, the system may cycle on and off. Comparing absolute Btu/h is useful even when two units have the same advertised size. The cooling sound range shows what happens between the quietest and highest published fan settings. Smaller dB(A) values indicate lower measured sound pressure. Fan speed and the room itself affect what you hear. Reading an indoor fan sound rating
Two 12,000 Btu/h systems
Both pairs below have the same rated cooling output. One is cheaper to buy and delivers more heat at 5°F. The other can run at a lower cooling output when a room needs less cooling. Dollar estimates use the starting loads and rate above.
| Measurement | ACiQ Platinum | Mitsubishi GX |
|---|---|---|
| Equipment price | $1,649.99 | $2,676.16 |
| Equipment and ten years of electricity | $4,072.94 | $5,061.53 |
| Heat delivered at 5°F | 11,500 Btu/h | 10,100 Btu/h |
| Equipment price per 1,000 Btu/h at 5°F | $143.48 | $264.97 |
| Minimum heating at 47°F | 3,800 Btu/h | 1,500 Btu/h |
| Minimum cooling at 95°F | 3,800 Btu/h | 1,300 Btu/h |
Who writes the guides and how the site is funded
MiniSplit Scout publishes this U.S. equipment directory and its buying guides. For each matched pair, the model sheet lists the technical documents behind the numbers and the retailers behind the equipment price. Sound and output figures come from the published tests under the conditions shown.
The installation phone line may earn the site a referral fee when a homeowner calls. Equipment rankings use the selected measurement, the price sources listed on the model sheet and, for running costs, the electricity assumptions you choose.
What’s in this edition
103 single-zone wall-mounted systems documented for the U.S. market, across 9 brands. The size filter groups models by nominal size. Each model sheet also gives the rated cooling capacity, which can differ between two systems in the same size class.
Manufacturer submittals and engineering manuals supply most model-specific ratings. Some series use a manufacturer document hosted by a distributor, or a distributor sheet checked against the engineering manual. Product pages link to the material used.
For 43 pairs, both model numbers matched a U.S. ENERGY STAR record exactly. Another 21 matched model patterns published by EPA, where trailing asterisks cover permitted variants. For 10 pairs the registry names a related base model without the full suffix. These records are linked for reference and excluded from the winter rankings. For the remaining 29 pairs we found no matching row in the records checked. The latest model review is dated .
Retail prices and size-class benchmarks
We check U.S. retailer listings for the exact indoor and outdoor units. If a seller lists the units separately, we add its two prices. Each seller counts once. With two or more sellers we show their arithmetic mean, and with one we show the seller’s price. Each model sheet names the retailers, gives the recorded prices and dates the review. The seller details identify separately priced blocks, included kits and older listing snapshots where applicable. See what an installation quote covers.
Earlier price and efficiency score
The model sheets also carry a weighted benchmark from the original catalog. We group pairs by nominal cooling capacity. When a nominal size is unavailable, we use the size class closest to the rated cooling output. Within each class we take the median equipment price and the median of each efficiency rating. Each pair counts once, and each median requires at least two pairs with that measurement.
The score adds 40 × (median price ÷ pair price), 25 × (SEER2 ÷ median SEER2), 25 × (HSPF2 ÷ median HSPF2) and 10 × (EER2 ÷ median EER2). At all four medians the score is 100. For the efficiency-only benchmark, add the last three terms and divide by 0.60.
One retailer’s price makes this score provisional. Computing it requires at least two priced pairs in the class and all three efficiency ratings for the pair.
Additional reference calculations
We use fixed editorial references of 18 SEER2, 12 EER2, 9 HSPF2 and 30 dB(A). The first four formulas compare electricity use for the same useful load. Multiply each ratio by 100 to display a percentage. The sound margin is measured in decibels. A negative percentage means the system needs more electricity in that scenario. Rates, local weather and hours of operation determine the dollar amount on a bill.
Cooling electricity over a season
103 of 103 pairs1 − 18 ÷ SEER2For the same amount of heat removed, compare electricity use with a system rated 18 SEER2.
Electricity at the cooling test point
103 of 103 pairs1 − 12 ÷ EER2Compare input power for the same cooling output at the EER2 test point. The reference is 12 EER2.
Heating electricity over a season
103 of 103 pairs1 − 9 ÷ HSPF2Compare seasonal electricity use for the same heat delivered. The reference is 9 HSPF2 in climate Region IV.
Electricity across both seasons
103 of 103 pairs1 − [w ÷ SEER2 + (1 − w) ÷ HSPF2] ÷ [w ÷ 18 + (1 − w) ÷ 9]Here w is the share of useful heating and cooling load devoted to cooling. The catalog uses 0.5, giving equal weight to heat removed and heat delivered.
Heat retained at 5°F
64 of 103 pairsHeating output at 5°F ÷ rated heating output at 47°FBoth values come from the same ENERGY STAR record. A system that delivers more than its 47°F nominal rating at 5°F can show a result above 100%.
Cooling modulation depth
45 of 103 pairs1 − minimum cooling at 95°F ÷ rated cooling at 95°FThe percentage shows how far the system can turn down from rated cooling capacity at the same 95°F outdoor test point.
Indoor sound margin
67 of 103 pairs30 dB(A) − minimum indoor cooling sound pressureA positive value is the number of decibels below the chosen reference at the quietest published cooling setting. It says nothing about fan speed on a particular night.
Checking heating capacity retention
The Mitsubishi GX12 pair supplies 10,100 Btu/h at 5°F and has a 14,400 Btu/h heating rating at 47°F in its EPA record. Divide the first figure by the second to get 70.1%. The ACiQ Platinum 12k pair returns 95.8% using the same method. Their rated cooling capacities both happen to be 12,000 Btu/h.
When two sources differ
We cross-checked nominal cooling capacity, SEER2, EER2, HSPF2 and rated heat at 47°F where both records give comparable conditions. These are the differences we found. Cooling and seasonal comparisons use the manufacturer figure. The 5°F retention calculation always uses the two EPA figures together.
| Indoor unit | Rating | Manufacturer | EPA |
|---|---|---|---|
| LIV18HP230V1R32AH | EER2 | 12.35 | 12 |
| LIV18HP230V1R32AH | Rated heat at 47°F (Btu/h) | 19,100 | 17,000 |
| CS-XZ12AKUAW | EER2 | 14.35 | 15 |
| CS-XZ12AKUAW | Rated cooling capacity (Btu/h) | 11,500 | 12,000 |
| LIV24HP230V1R32AH | Rated heat at 47°F (Btu/h) | 24,000 | 22,400 |
Where a measurement is missing
N/A in a measurement column means we could not confirm that figure for the pair under the stated conditions. Cooling modulation requires a minimum capacity at 95°F. Indoor cooling noise requires a reading taken in cooling mode. A manufacturer’s general capacity range or an unspecified sound reading goes in its own context.
The cold-climate designation comes from the matching EPA entry when available. Separately, we calculate the percentage of heat retained. ENERGY STAR also considers efficiency and performance verification, so a high percentage alone cannot establish certification.