Panasonic ClimaPure XZ 12,000 Btu/h class
Panasonic rates this single-zone wall system for 11,500 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- CS-XZ12AKUAW
- Outdoor unit
- CU-XZ12AKUAC
Cost and room performance
Equipment and ten years of electricity
$6,353.91
- Listed equipment price
- $4,095.45 2 retailers
- Ten years of electricity
- $2,258.46
- Annual electricity use
- 1,254.7 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Scores by criterion
Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated
-
10-year equipment + electricity $6,353.9139 / 100
-
Price per 1,000 Btu/h at 5°F $298.945 / 100
-
Heat available at 5°F 13,700 Btu/h34 / 100
-
Electricity for 1 million Btu at 5°F 138.9 kWh51 / 100
-
Minimum heat at 47°F N/AN/A / 100
-
Minimum cooling at 95°F N/AN/A / 100
-
Indoor sound, lowest fan 19 dB(A)100 / 100
-
Indoor sound, highest fan 44 dB(A)71 / 100
-
Electricity for 1 million Btu of cooling 40 kWh62 / 100
-
Electricity for 1 million Btu of heat 85.5 kWh69 / 100
-
Equipment price $4,095.4522 / 100
-
Heat retained at 5°F 119.1%74 / 100
-
Seasonal cooling efficiency 25 SEER244 / 100
-
Earlier weighted value score 85.1 (size-class reference of 100)0 / 100
Electricity per million Btu
- Cooling
- 40 kWh
- Heating · Region IV rating
- 85.5 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- $298.94
- Heat available at 5°F
- 13,700 Btu/h
- COP at 5°F
- 2.11
- Electricity per million Btu at 5°F
- 138.9 kWh
EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- N/A
- Minimum cooling output at 95°F
- N/A
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 19–44 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment price & installation
- Average equipment price
- $4,095.45
- 2 retailers · $3,879.90 to $4,311 · Price sources reviewed
Prices cover the listed equipment package. Installation, tax and shipping are separate.
What would the whole job cost?
Ask for an estimate for the CS-XZ12AKUAW and CU-XZ12AKUAC, including labor, refrigerant lines and electrical work.
Equipment price sources
- Klondike AC & Heating$3,879.90
- KPaul SupplyIndoor unit $1,863.94 + outdoor unit $2,447.06$4,311
The median equipment price in the 12,000 Btu/h class is $1,980.95 (29 of 29 systems priced).
Earlier price and efficiency score
Weighted score 85.1. The reference for the 12,000 Btu/h class is 100.
Efficiency-only benchmark 109.6.
Published specifications
Cooling
| Rated cooling capacity | 11,500 Btu/h |
|---|---|
| Published minimum · outdoor temperature unspecified | 2,900 Btu/h |
| Published maximum · outdoor temperature unspecified | 16,100 Btu/h |
| Seasonal efficiency (SEER2) | 25 Btu/Wh |
| Efficiency at the rating point (EER2) | 14.35 Btu/Wh |
| Lower published outdoor operating limit | 0 °F |
| Upper published outdoor operating limit | 114.8 °F |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 11.7 Btu/Wh |
|---|---|
| Nominal output · outdoor temperature unspecified | 12,000 Btu/h |
| Rated output at 17°F | 16,500 Btu/h |
| Maximum output at 5°F | 13,700 Btu/h |
| Published minimum · outdoor temperature unspecified | 3,200 Btu/h |
| Published maximum · outdoor temperature unspecified | 23,600 Btu/h |
| Lower published outdoor operating limit | -15 °F |
| Upper published outdoor operating limit | 75.2 °F |
Sound levels
| Indoor, cooling · quietest setting | 19 dB(A) |
|---|---|
| Indoor, cooling · low fan | 28 dB(A) |
| Indoor, cooling · highest published level | 44 dB(A) |
| Indoor cooling fan stages · published order | 44 / 28 / 19 dB(A) |
| Outdoor unit in cooling mode | 48 dB(A) |
Installation details
| Power supply | 208–230 V / 1 Ph / 60 Hz |
|---|---|
| Refrigerant | R-32 |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Standard compressor coverage | 7 years |
A qualifying Gold Star installation can extend coverage to 12 years. Consult the program terms for the installation on your quote.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 28.0% |
|---|---|
| Cooling input reduction at the EER2 test point | 16.4% |
| Seasonal heating electricity savings | 23.1% |
| Electricity savings with equal heating and cooling loads | 24.7% |
| Heat at 5°F as a share of rated heat at 47°F | 119.1% |
| Cooling turndown below rated capacity at 95°F | N/A |
| Quietest cooling mode below a 30 dB(A) reference | 11 dB(A) |
ENERGY STAR cross-check
The ENERGY STAR listing names both units on this sheet.
| ENERGY STAR ID | 4437550 |
|---|---|
| AHRI reference | 214837753 |
| Cold Climate designation | Yes |
| Rated cooling | 12,000 Btu/h |
| Heating at 47°F | 11,500 Btu/h |
| Heating at 17°F | 16,500 Btu/h |
| Heating at 5°F | 13,700 Btu/h |
| COP at 5°F | 2.11 |
| SEER2 | 25 Btu/Wh |
| EER2 | 15 Btu/Wh |
| HSPF2 | 11.7 Btu/Wh |
| 5°F output as a share of 47°F rated output | 119.13% |
Reading the sources
The model sheet and the ENERGY STAR listing give different values. The catalog uses the equipment document for cooling capacity and efficiency.
| Measurement | Equipment document | ENERGY STAR |
|---|---|---|
| EER2 | 14.35 | 15 |
| Rated cooling capacity (Btu/h) | 11,500 | 12,000 |
Panasonic labels its fan settings High, Low and Quiet-Low. The lowest number uses Quiet-Low. The nominal heating figure in the submittal has no stated outdoor temperature.