Panasonic ClimaPure XZ 15,000 Btu/h class

Panasonic rates this single-zone wall system for 14,700 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
CS-XZ15AKUAW
Outdoor unit
CU-XZ15AKUAC

Cost and room performance

Equipment and ten years of electricity

$6,798.96

Listed equipment price
$4,495.39 2 retailers
Ten years of electricity
$2,303.57
Annual electricity use
1,279.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $6,798.96
    30 / 100
  • Price per 1,000 Btu/h at 5°F $293.82
    7 / 100
  • Heat available at 5°F 15,300 Btu/h
    43 / 100
  • Electricity for 1 million Btu at 5°F 136.9 kWh
    55 / 100
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan 30 dB(A)
    39 / 100
  • Indoor sound, highest fan 45 dB(A)
    64 / 100
  • Electricity for 1 million Btu of cooling 44.6 kWh
    47 / 100
  • Electricity for 1 million Btu of heat 83.3 kWh
    73 / 100
  • Equipment price $4,495.39
    13 / 100
  • Heat retained at 5°F 104.1%
    55 / 100
  • Seasonal cooling efficiency 22.4 SEER2
    30 / 100
  • Earlier weighted value score 91.8 (size-class reference of 100)
    9 / 100

Electricity per million Btu

Cooling
44.6 kWh
Heating · Region IV rating
83.3 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$293.82
Heat available at 5°F
15,300 Btu/h
COP at 5°F
2.14
Electricity per million Btu at 5°F
136.9 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
30–45 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Average equipment price
$4,495.39
2 retailers · $4,258.79 to $4,731.99 · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the CS-XZ15AKUAW and CU-XZ15AKUAC, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Klondike AC & Heating
    $4,258.79
  • KPaul SupplyIndoor unit $2,041.40 + outdoor unit $2,690.59
    $4,731.99

What an installation quote covers

The median equipment price in the 15,000 Btu/h class is $3,293.23 (8 of 8 systems priced).

Earlier price and efficiency score

Weighted score 91.8. The reference for the 15,000 Btu/h class is 100.

Efficiency-only benchmark 104.2.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity14,700 Btu/h
Published minimum · outdoor temperature unspecified3,300 Btu/h
Published maximum · outdoor temperature unspecified19,300 Btu/h
Seasonal efficiency (SEER2)22.4 Btu/Wh
Efficiency at the rating point (EER2)13.35 Btu/Wh
Lower published outdoor operating limit0 °F
Upper published outdoor operating limit114.8 °F
Heating
Seasonal efficiency (HSPF2, Region IV)12 Btu/Wh
Nominal output · outdoor temperature unspecified17,200 Btu/h
Rated output at 17°F17,500 Btu/h
Maximum output at 5°F15,300 Btu/h
Published minimum · outdoor temperature unspecified3,300 Btu/h
Published maximum · outdoor temperature unspecified25,200 Btu/h
Lower published outdoor operating limit-15 °F
Upper published outdoor operating limit75.2 °F
Sound levels
Indoor, cooling · quietest setting30 dB(A)
Indoor, cooling · low fan37 dB(A)
Indoor, cooling · highest published level45 dB(A)
Indoor cooling fan stages · published order45 / 37 / 30 dB(A)
Outdoor unit in cooling mode50 dB(A)
Installation details
Power supply208–230 V / 1 Ph / 60 Hz
RefrigerantR-32
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

A qualifying Gold Star installation can extend coverage to 12 years. Consult the program terms for the installation on your quote.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings19.6%
Cooling input reduction at the EER2 test point10.1%
Seasonal heating electricity savings25.0%
Electricity savings with equal heating and cooling loads23.2%
Heat at 5°F as a share of rated heat at 47°F104.1%
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) reference0 dB(A)

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID4437551
AHRI reference214837754
Cold Climate designationYes
Rated cooling14,700 Btu/h
Heating at 47°F14,700 Btu/h
Heating at 17°F17,500 Btu/h
Heating at 5°F15,300 Btu/h
COP at 5°F2.14
SEER222.4 Btu/Wh
EER213.35 Btu/Wh
HSPF212 Btu/Wh
5°F output as a share of 47°F rated output104.08%

Reading the sources

Panasonic labels its fan settings High, Low and Quiet-Low. The lowest number uses Quiet-Low. The nominal heating figure in the submittal has no stated outdoor temperature.

minisplitscout.com/systems/cs-xz15akuaw--cu-xz15akuac/