GREE Livo R32 9,000 Btu/h class

GREE rates this single-zone wall system for 9,100 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
LIV09HP230V1R32AH
Outdoor unit
LIV09HP230V1R32AO

Cost and room performance

Equipment and ten years of electricity

$4,472

Listed equipment price
$1,548.50 2 retailers
Ten years of electricity
$2,923.50
Annual electricity use
1,624.2 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $4,472.00
    77 / 100
  • Price per 1,000 Btu/h at 5°F $203.75
    50 / 100
  • Heat available at 5°F 7,600 Btu/h
    1 / 100
  • Electricity for 1 million Btu at 5°F 151.1 kWh
    29 / 100
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan 21 dB(A)
    89 / 100
  • Indoor sound, highest fan 42 dB(A)
    86 / 100
  • Electricity for 1 million Btu of cooling 48.8 kWh
    33 / 100
  • Electricity for 1 million Btu of heat 113.6 kWh
    20 / 100
  • Equipment price $1,548.50
    81 / 100
  • Heat retained at 5°F 76%
    19 / 100
  • Seasonal cooling efficiency 20.5 SEER2
    19 / 100
  • Earlier weighted value score 98.3 (size-class reference of 100)
    17 / 100

Electricity per million Btu

Cooling
48.8 kWh
Heating · Region IV rating
113.6 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$203.75
Heat available at 5°F
7,600 Btu/h
COP at 5°F
1.94
Electricity per million Btu at 5°F
151.1 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
21–42 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Average equipment price
$1,548.50
2 retailers · $1,267 to $1,830 · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the LIV09HP230V1R32AH and LIV09HP230V1R32AO, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • SupplyHouseSeller accepts backorders.
    $1,267
  • PTAC Direct
    $1,830

What an installation quote covers

The median equipment price in the 9,000 Btu/h class is $1,876.44 (26 of 26 systems priced).

Earlier price and efficiency score

Weighted score 98.3. The reference for the 9,000 Btu/h class is 100.

Efficiency-only benchmark 83.1.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity9,100 Btu/h
Published minimum · outdoor temperature unspecified2,388 Btu/h
Published maximum · outdoor temperature unspecified10,300 Btu/h
Seasonal efficiency (SEER2)20.5 Btu/Wh
Efficiency at the rating point (EER2)12.5 Btu/Wh
Moisture removal1.69 US pt/h
Lower published outdoor operating limit0 °F
Upper published outdoor operating limit118 °F
Heating
Seasonal efficiency (HSPF2, Region IV)8.8 Btu/Wh
Rated output at 47°F10,000 Btu/h
Maximum output at 47°F13,136 Btu/h
Rated output at 17°F8,100 Btu/h
Maximum output at 17°F10,246 Btu/h
Rated output at 5°F7,600 Btu/h
Maximum output at 5°F9,327 Btu/h
Published minimum · outdoor temperature unspecified2,217 Btu/h
Published maximum · outdoor temperature unspecified13,136 Btu/h
COP at 5°F · rated output1.94
COP at 5°F · maximum output2.47
Power at 5°F · maximum output1,106 W
Lower published outdoor operating limit-13 °F
Upper published outdoor operating limit75 °F
Sound levels
Indoor, cooling · quietest setting21 dB(A)
Indoor, cooling · highest published level42 dB(A)
Indoor cooling fan stages · published order42 / 39 / 37 / 36 / 28 / 25 / 23 / 21 dB(A)
Outdoor · operating mode unspecified51 dB(A)
Installation details
Power supply208–230 V / 1 Ph / 60 Hz
RefrigerantR-32
Minimum circuit ampacity10 A
Maximum overcurrent protection15 A
Maximum line-set length66 ft
Maximum vertical separation40 ft
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

A qualifying GREE Select installation and registration can extend coverage to 10 years. The linked warranty program lists the conditions.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings12.2%
Cooling input reduction at the EER2 test point4.0%
Seasonal heating electricity savings-2.3%
Electricity savings with equal heating and cooling loads2.5%
Heat at 5°F as a share of rated heat at 47°F76.0%
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) reference9 dB(A)

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID4511788
AHRI reference214779524
Cold Climate designationYes
Rated cooling9,100 Btu/h
Heating at 47°F10,000 Btu/h
Heating at 17°F9,600 Btu/h
Heating at 5°F7,600 Btu/h
COP at 5°F1.94
SEER220.5 Btu/Wh
EER212.5 Btu/Wh
HSPF28.8 Btu/Wh
5°F output as a share of 47°F rated output76%

Reading the sources

GREE’s extended heating tables use full output with a 70°F indoor dry-bulb temperature. The system submittal reports rated output separately.

minisplitscout.com/systems/liv09hp230v1r32ah--liv09hp230v1r32ao/