Daikin POLARA 36,000 Btu/h class

Daikin rates this single-zone wall system for 34,400 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXV36AVJU9
Outdoor unit
RXV36AVJU9

Cost and room performance

Equipment and ten years of electricity

$8,304.21

Listed equipment price
$5,054.21 single retailer
Ten years of electricity
$3,250
Annual electricity use
1,805.6 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $8,304.21
    0 / 100
  • Price per 1,000 Btu/h at 5°F N/A
    N/A
  • Heat available at 5°F N/A
    N/A
  • Electricity for 1 million Btu at 5°F N/A
    N/A
  • Minimum heat at 47°F 10,200 Btu/h
    16 / 100
  • Minimum cooling at 95°F 10,200 Btu/h
    21 / 100
  • Indoor sound, lowest fan 37 dB(A)
    0 / 100
  • Indoor sound, highest fan 54 dB(A)
    0 / 100
  • Electricity for 1 million Btu of cooling 55.6 kWh
    11 / 100
  • Electricity for 1 million Btu of heat 125 kWh
    0 / 100
  • Equipment price $5,054.21
    0 / 100
  • Heat retained at 5°F N/A
    N/A
  • Seasonal cooling efficiency 18 SEER2
    6 / 100
  • Earlier weighted value score N/A
    N/A

Electricity per million Btu

Cooling
55.6 kWh
Heating · Region IV rating
125 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
N/A
Heat available at 5°F
N/A
COP at 5°F
N/A
Electricity per million Btu at 5°F
N/A

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
10,200 Btu/h
Minimum cooling output at 95°F
10,200 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
37–54 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$5,054.21
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the FTXV36AVJU9 and RXV36AVJU9, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Got Ductless
    $5,054.21

What an installation quote covers

Earlier price and efficiency score

Weighted score N/A. A second system in the 36,000 Btu/h class is needed for a same-size benchmark.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity34,400 Btu/h
Marketed size class36,000 Btu/h
Minimum output at 95°F10,200 Btu/h
Maximum output at 95°F34,400 Btu/h
Seasonal efficiency (SEER2)18 Btu/Wh
Efficiency at the rating point (EER2)9.8 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)8 Btu/Wh
Rated output at 47°F36,000 Btu/h
Minimum output at 47°F10,200 Btu/h
Maximum output at 47°F36,000 Btu/h
Sound levels
Indoor, cooling · quietest setting37 dB(A)
Indoor, cooling · highest published level54 dB(A)
Indoor, heating · quietest setting35 dB(A)
Indoor, heating · highest published level54 dB(A)
Outdoor unit in cooling mode60 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Specified breaker size25 A
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings0.0%
Cooling input reduction at the EER2 test point-22.4%
Seasonal heating electricity savings-12.5%
Electricity savings with equal heating and cooling loads-8.3%
Heat at 5°F as a share of rated heat at 47°FN/A
Cooling turndown below rated capacity at 95°F70.3%
Quietest cooling mode below a 30 dB(A) reference-7 dB(A)

ENERGY STAR cross-check

The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.

Reading the sources

Daikin US shows both model numbers in the same system specification table on PDF page 40.

Indoor sound pressure is the cooling/heating H/M/L/SL fan-speed row on the catalog page. Minima and maxima correspond to SL and H. The pair-specific capacity source specifies 95°F outdoor dry-bulb in cooling and 47°F outdoor dry-bulb in heating, with rated, minimum and maximum capacities. Use the exact submittal PDF page 4 for outdoor high-speed sound, with cooling column in catalog as supporting context.

minisplitscout.com/systems/ftxv36avju9--rxv36avju9/