Daikin POLARA 30,000 Btu/h class
Daikin rates this single-zone wall system for 31,400 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- FTXV30AVJU9
- Outdoor unit
- RXV30AVJU9
Cost and room performance
Equipment and ten years of electricity
$6,602.59
- Listed equipment price
- $3,433 single retailer
- Ten years of electricity
- $3,169.59
- Annual electricity use
- 1,760.9 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Scores by criterion
Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated
-
10-year equipment + electricity $6,602.5934 / 100
-
Price per 1,000 Btu/h at 5°F N/AN/A / 100
-
Heat available at 5°F N/AN/A / 100
-
Electricity for 1 million Btu at 5°F N/AN/A / 100
-
Minimum heat at 47°F 10,200 Btu/h16 / 100
-
Minimum cooling at 95°F 10,200 Btu/h21 / 100
-
Indoor sound, lowest fan 37 dB(A)0 / 100
-
Indoor sound, highest fan 53 dB(A)7 / 100
-
Electricity for 1 million Btu of cooling 52.6 kWh21 / 100
-
Electricity for 1 million Btu of heat 123.5 kWh3 / 100
-
Equipment price $3,433.0038 / 100
-
Heat retained at 5°F N/AN/A / 100
-
Seasonal cooling efficiency 19 SEER211 / 100
-
Earlier weighted value score 104.2 (size-class reference of 100)25 / 100
Electricity per million Btu
- Cooling
- 52.6 kWh
- Heating · Region IV rating
- 123.5 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- N/A
- Heat available at 5°F
- N/A
- COP at 5°F
- N/A
- Electricity per million Btu at 5°F
- N/A
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 10,200 Btu/h
- Minimum cooling output at 95°F
- 10,200 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 37–53 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment price & installation
- Single retailer price
- $3,433
- 1 retailer · Price sources reviewed
Prices cover the listed equipment package. Installation, tax and shipping are separate.
What would the whole job cost?
Ask for an estimate for the FTXV30AVJU9 and RXV30AVJU9, including labor, refrigerant lines and electrical work.
The median equipment price in the 30,000 Btu/h class is $4,006.70 (3 of 3 systems priced).
Earlier price and efficiency score
Weighted score 104.2. Provisional · Based on one retailer. The reference for the 30,000 Btu/h class is 100.
Efficiency-only benchmark 95.8.
Published specifications
Cooling
| Rated cooling capacity | 31,400 Btu/h |
|---|---|
| Marketed size class | 30,000 Btu/h |
| Minimum output at 95°F | 10,200 Btu/h |
| Maximum output at 95°F | 31,400 Btu/h |
| Seasonal efficiency (SEER2) | 19 Btu/Wh |
| Efficiency at the rating point (EER2) | 10 Btu/Wh |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 8.1 Btu/Wh |
|---|---|
| Rated output at 47°F | 34,800 Btu/h |
| Minimum output at 47°F | 10,200 Btu/h |
| Maximum output at 47°F | 34,800 Btu/h |
Sound levels
| Indoor, cooling · quietest setting | 37 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 53 dB(A) |
| Indoor, heating · quietest setting | 35 dB(A) |
| Indoor, heating · highest published level | 54 dB(A) |
| Outdoor unit in cooling mode | 57 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-32 |
| Specified breaker size | 25 A |
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 5.3% |
|---|---|
| Cooling input reduction at the EER2 test point | -20.0% |
| Seasonal heating electricity savings | -11.1% |
| Electricity savings with equal heating and cooling loads | -5.7% |
| Heat at 5°F as a share of rated heat at 47°F | N/A |
| Cooling turndown below rated capacity at 95°F | 67.5% |
| Quietest cooling mode below a 30 dB(A) reference | -7 dB(A) |
ENERGY STAR cross-check
The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.
Reading the sources
Daikin US shows both model numbers in the same system specification table on PDF page 40.
Indoor sound pressure is the cooling/heating H/M/L/SL fan-speed row on the catalog page. Minima and maxima correspond to SL and H. The pair-specific capacity source specifies 95°F outdoor dry-bulb in cooling and 47°F outdoor dry-bulb in heating, with rated, minimum and maximum capacities. Use the exact submittal PDF page 4 for outdoor high-speed sound, with cooling column in catalog as supporting context.