Daikin ATMOSPHERA 24,000 Btu/h class
Daikin rates this single-zone wall system for 21,600 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- FTXM24WVJU9
- Outdoor unit
- RXM24WVJU9
Cost and room performance
Equipment and ten years of electricity
$7,556.18
- Listed equipment price
- $4,938 2 retailers
- Ten years of electricity
- $2,618.18
- Annual electricity use
- 1,454.5 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Scores by criterion
Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated
-
10-year equipment + electricity $7,556.1815 / 100
-
Price per 1,000 Btu/h at 5°F N/AN/A / 100
-
Heat available at 5°F N/AN/A / 100
-
Electricity for 1 million Btu at 5°F N/AN/A / 100
-
Minimum heat at 47°F 9,000 Btu/h27 / 100
-
Minimum cooling at 95°F 9,000 Btu/h32 / 100
-
Indoor sound, lowest fan 34 dB(A)17 / 100
-
Indoor sound, highest fan 51 dB(A)21 / 100
-
Electricity for 1 million Btu of cooling 45.5 kWh44 / 100
-
Electricity for 1 million Btu of heat 100 kWh44 / 100
-
Equipment price $4,938.003 / 100
-
Heat retained at 5°F N/AN/A / 100
-
Seasonal cooling efficiency 22 SEER228 / 100
-
Earlier weighted value score 89.2 (size-class reference of 100)5 / 100
Electricity per million Btu
- Cooling
- 45.5 kWh
- Heating · Region IV rating
- 100 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- N/A
- Heat available at 5°F
- N/A
- COP at 5°F
- N/A
- Electricity per million Btu at 5°F
- N/A
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 9,000 Btu/h
- Minimum cooling output at 95°F
- 9,000 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 34–51 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment price & installation
- Average equipment price
- $4,938
- 2 retailers · $4,755 to $5,121 · Price sources reviewed
Prices cover the listed equipment package. Installation, tax and shipping are separate.
What would the whole job cost?
Ask for an estimate for the FTXM24WVJU9 and RXM24WVJU9, including labor, refrigerant lines and electrical work.
The median equipment price in the 24,000 Btu/h class is $3,299 (15 of 15 systems priced).
Earlier price and efficiency score
Weighted score 89.2. The reference for the 24,000 Btu/h class is 100.
Efficiency-only benchmark 104.2.
Published specifications
Cooling
| Rated output at 95°F | 21,600 Btu/h |
|---|---|
| Minimum output at 95°F | 9,000 Btu/h |
| Maximum output at 95°F | 26,000 Btu/h |
| Seasonal efficiency (SEER2) | 22 Btu/Wh |
| Efficiency at the rating point (EER2) | 12 Btu/Wh |
The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.
Heating
| Seasonal efficiency (HSPF2, Region IV) | 10 Btu/Wh |
|---|---|
| Rated output at 47°F | 24,000 Btu/h |
| Minimum output at 47°F | 9,000 Btu/h |
| Maximum output at 47°F | 32,200 Btu/h |
| Maximum output at 5°F | 24,000 Btu/h |
| Maximum output at −13°F | 18,000 Btu/h |
| COP at 5°F · rated output | 1.8 |
Sound levels
| Indoor, cooling · quietest setting | 34 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 51 dB(A) |
| Indoor, heating · quietest setting | 34 dB(A) |
| Indoor, heating · highest published level | 51 dB(A) |
| Outdoor unit in cooling mode | 55 dB(A) |
| Outdoor unit in heating mode | 56 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-32 |
| Maximum overcurrent protection | 20 A |
| Maximum line-set length | 98.5 ft |
| Indoor unit weight | 33 lb |
| Outdoor unit weight | 132 lb |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Extended parts coverage · conditions apply | 12 years |
Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 18.2% |
|---|---|
| Cooling input reduction at the EER2 test point | 0.0% |
| Seasonal heating electricity savings | 10.0% |
| Electricity savings with equal heating and cooling loads | 12.7% |
| Heat at 5°F as a share of rated heat at 47°F | N/A |
| Cooling turndown below rated capacity at 95°F | 58.3% |
| Quietest cooling mode below a 30 dB(A) reference | -4 dB(A) |
ENERGY STAR cross-check
The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.