Daikin ATMOSPHERA 18,000 Btu/h class

Daikin rates this single-zone wall system for 18,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXM18WVJU9
Outdoor unit
RXM18WVJU9

Cost and room performance

Equipment and ten years of electricity

$6,958.45

Listed equipment price
$4,365.50 2 retailers
Ten years of electricity
$2,592.95
Annual electricity use
1,440.5 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $6,958.45
    27 / 100
  • Price per 1,000 Btu/h at 5°F N/A
    N/A
  • Heat available at 5°F N/A
    N/A
  • Electricity for 1 million Btu at 5°F N/A
    N/A
  • Minimum heat at 47°F 9,000 Btu/h
    27 / 100
  • Minimum cooling at 95°F 9,000 Btu/h
    32 / 100
  • Indoor sound, lowest fan 33 dB(A)
    22 / 100
  • Indoor sound, highest fan 49 dB(A)
    36 / 100
  • Electricity for 1 million Btu of cooling 44.1 kWh
    49 / 100
  • Electricity for 1 million Btu of heat 100 kWh
    44 / 100
  • Equipment price $4,365.50
    16 / 100
  • Heat retained at 5°F N/A
    N/A
  • Seasonal cooling efficiency 22.7 SEER2
    32 / 100
  • Earlier weighted value score 90.8 (size-class reference of 100)
    7 / 100

Electricity per million Btu

Cooling
44.1 kWh
Heating · Region IV rating
100 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
N/A
Heat available at 5°F
N/A
COP at 5°F
N/A
Electricity per million Btu at 5°F
N/A

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
9,000 Btu/h
Minimum cooling output at 95°F
9,000 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
33–49 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Average equipment price
$4,365.50
2 retailers · $4,204 to $4,527 · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the FTXM18WVJU9 and RXM18WVJU9, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Got Ductless
    $4,204
  • The AC Outlet
    $4,527

What an installation quote covers

The median equipment price in the 18,000 Btu/h class is $3,099.75 (18 of 18 systems priced).

Earlier price and efficiency score

Weighted score 90.8. The reference for the 18,000 Btu/h class is 100.

Efficiency-only benchmark 103.9.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F18,000 Btu/h
Minimum output at 95°F9,000 Btu/h
Maximum output at 95°F22,000 Btu/h
Seasonal efficiency (SEER2)22.7 Btu/Wh
Efficiency at the rating point (EER2)12.5 Btu/Wh

The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.

Heating
Seasonal efficiency (HSPF2, Region IV)10 Btu/Wh
Rated output at 47°F21,600 Btu/h
Minimum output at 47°F9,000 Btu/h
Maximum output at 47°F30,200 Btu/h
Maximum output at 5°F21,600 Btu/h
Maximum output at −13°F16,200 Btu/h
COP at 5°F · rated output1.8
Sound levels
Indoor, cooling · quietest setting33 dB(A)
Indoor, cooling · highest published level49 dB(A)
Indoor, heating · quietest setting32 dB(A)
Indoor, heating · highest published level49 dB(A)
Outdoor unit in cooling mode54 dB(A)
Outdoor unit in heating mode55 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Maximum overcurrent protection20 A
Maximum line-set length98.5 ft
Indoor unit weight33 lb
Outdoor unit weight132 lb
Warranty
Standard parts coverage5 years
Extended parts coverage · conditions apply12 years

Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings20.7%
Cooling input reduction at the EER2 test point4.0%
Seasonal heating electricity savings10.0%
Electricity savings with equal heating and cooling loads13.6%
Heat at 5°F as a share of rated heat at 47°FN/A
Cooling turndown below rated capacity at 95°F50.0%
Quietest cooling mode below a 30 dB(A) reference-3 dB(A)

ENERGY STAR cross-check

The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.