Pioneer Quantum Hyperformance 12,000 Btu/h class

Pioneer rates this single-zone wall system for 12,000 Btu/h of cooling. It uses a 208/230V supply and R-454B refrigerant.

Indoor unit
WT012GLSI25HLH
Outdoor unit
YN012GLSI25RPH
System SKU
WYT012GLSI25RH

Cost and room performance

Equipment and ten years of electricity

$3,722.29

Listed equipment price
$1,288 single retailer
Ten years of electricity
$2,434.29
Annual electricity use
1,352.4 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $3,722.29
    92 / 100
  • Price per 1,000 Btu/h at 5°F $107.33
    95 / 100
  • Heat available at 5°F 12,000 Btu/h
    25 / 100
  • Electricity for 1 million Btu at 5°F 162.8 kWh
    8 / 100
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan N/A
    N/A
  • Indoor sound, highest fan N/A
    N/A
  • Electricity for 1 million Btu of cooling 40 kWh
    62 / 100
  • Electricity for 1 million Btu of heat 95.2 kWh
    52 / 100
  • Equipment price $1,288.00
    87 / 100
  • Heat retained at 5°F 100%
    50 / 100
  • Seasonal cooling efficiency 25 SEER2
    44 / 100
  • Earlier weighted value score 124.1 (size-class reference of 100)
    50 / 100

Electricity per million Btu

Cooling
40 kWh
Heating · Region IV rating
95.2 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$107.33
Heat available at 5°F
12,000 Btu/h
COP at 5°F
1.8
Electricity per million Btu at 5°F
162.8 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
N/A

A cooling-mode fan range is unavailable in the model documents.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$1,288
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the WT012GLSI25HLH and YN012GLSI25RPH, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Pioneer Official StoreIndoor and outdoor equipment without a line set.
    $1,288

What an installation quote covers

The median equipment price in the 12,000 Btu/h class is $1,980.95 (29 of 29 systems priced).

Earlier price and efficiency score

Weighted score 124.1. Provisional · Based on one retailer. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 104.2.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity12,000 Btu/h
Marketed size class12,000 Btu/h
Published minimum · outdoor temperature unspecified2,500 Btu/h
Published maximum · outdoor temperature unspecified15,600 Btu/h
Seasonal efficiency (SEER2)25 Btu/Wh
Efficiency at the rating point (EER2)14 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)10.5 Btu/Wh
Rated output at 47°F12,000 Btu/h
Output at 17°F · load unspecified14,000 Btu/h
Output at 5°F · load unspecified12,000 Btu/h
Published minimum · outdoor temperature unspecified2,500 Btu/h
Published maximum · outdoor temperature unspecified19,700 Btu/h
Published COP at 5°F · load unspecified1.8
Sound levels
Indoor fan settings · operating mode unspecified46 / 44 / 36 / 32 / 30 dB(A)
Installation details
Power supply208/230V
RefrigerantR-454B
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings28.0%
Cooling input reduction at the EER2 test point14.3%
Seasonal heating electricity savings14.3%
Electricity savings with equal heating and cooling loads18.9%
Heat at 5°F as a share of rated heat at 47°F100.0%
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) referenceN/A

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3999470
AHRI reference217048755
Cold Climate designationYes
Rated cooling12,000 Btu/h
Heating at 47°F12,000 Btu/h
Heating at 17°F14,000 Btu/h
Heating at 5°F12,000 Btu/h
COP at 5°F1.8
SEER225 Btu/Wh
EER214 Btu/Wh
HSPF210.5 Btu/Wh
5°F output as a share of 47°F rated output100%

Reading the sources

The US manufacturer product page explicitly names the indoor and outdoor part numbers for this single-zone high-wall heat pump.