Pioneer Diamante Essenza 9,000 Btu/h class

Pioneer rates this single-zone wall system for 9,000 Btu/h of cooling. It uses a 110/120V supply and R-32 refrigerant.

Indoor unit
WT009ALUI20HLE
Outdoor unit
YN009ALUI20RPE
System SKU
WYT009ALUI20RL

Cost and room performance

Equipment and ten years of electricity

$3,632.74

Listed equipment price
$838 single retailer
Ten years of electricity
$2,794.74
Annual electricity use
1,552.6 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $3,632.74
    94 / 100
  • Price per 1,000 Btu/h at 5°F N/A
    N/A
  • Heat available at 5°F N/A
    N/A
  • Electricity for 1 million Btu at 5°F N/A
    N/A
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan N/A
    N/A
  • Indoor sound, highest fan N/A
    N/A
  • Electricity for 1 million Btu of cooling 50 kWh
    29 / 100
  • Electricity for 1 million Btu of heat 105.3 kWh
    34 / 100
  • Equipment price $838.00
    98 / 100
  • Heat retained at 5°F N/A
    N/A
  • Seasonal cooling efficiency 20 SEER2
    17 / 100
  • Earlier weighted value score 140.3 (size-class reference of 100)
    71 / 100

Electricity per million Btu

Cooling
50 kWh
Heating · Region IV rating
105.3 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
N/A
Heat available at 5°F
N/A
COP at 5°F
N/A
Electricity per million Btu at 5°F
N/A

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
N/A

A cooling-mode fan range is unavailable in the model documents.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$838
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the WT009ALUI20HLE and YN009ALUI20RPE, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Pioneer Official StoreIndoor and outdoor equipment bundled with a 16-foot installation kit.
    $838

What an installation quote covers

The median equipment price in the 9,000 Btu/h class is $1,876.44 (26 of 26 systems priced).

Earlier price and efficiency score

Weighted score 140.3. Provisional · Based on one retailer. The reference for the 9,000 Btu/h class is 100.

Efficiency-only benchmark 84.6.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity9,000 Btu/h
Marketed size class9,000 Btu/h
Published minimum · outdoor temperature unspecified3,400 Btu/h
Published maximum · outdoor temperature unspecified13,000 Btu/h
Seasonal efficiency (SEER2)20 Btu/Wh
Efficiency at the rating point (EER2)12 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)9.5 Btu/Wh
Rated output at 47°F10,000 Btu/h
Output at 17°F · load unspecified9,800 Btu/h
Output at 5°F · load unspecified8,000 Btu/h
Published minimum · outdoor temperature unspecified3,400 Btu/h
Published maximum · outdoor temperature unspecified13,900 Btu/h
Published COP at 5°F · load unspecified1.8
Sound levels
Indoor fan settings · operating mode unspecified42 / 39 / 34 / 30 / 28 dB(A)
Installation details
Power supply110/120V
RefrigerantR-32
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings10.0%
Cooling input reduction at the EER2 test point0.0%
Seasonal heating electricity savings5.3%
Electricity savings with equal heating and cooling loads6.8%
Heat at 5°F as a share of rated heat at 47°FN/A
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) referenceN/A

ENERGY STAR cross-check

The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.

Reading the sources

The US manufacturer product page explicitly names the indoor and outdoor part numbers for this single-zone high-wall heat pump.

minisplitscout.com/systems/wt009alui20hle--yn009alui20rpe/