GREE Vireo R32 12,000 Btu/h class

GREE rates this single-zone wall system for 12,000 Btu/h of cooling. It uses a 115 V supply and R-32 refrigerant.

Indoor unit
VIR12HP115V1R32AH
Outdoor unit
VIR12HP115V1R32AO

Cost and room performance

Equipment and ten years of electricity

$4,424.43

Listed equipment price
$1,795 single retailer
Ten years of electricity
$2,629.43
Annual electricity use
1,460.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $4,424.43
    78 / 100
  • Price per 1,000 Btu/h at 5°F $188.95
    57 / 100
  • Heat available at 5°F 9,500 Btu/h
    11 / 100
  • Electricity for 1 million Btu at 5°F 150.3 kWh
    31 / 100
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan N/A
    N/A
  • Indoor sound, highest fan N/A
    N/A
  • Electricity for 1 million Btu of cooling 40.8 kWh
    60 / 100
  • Electricity for 1 million Btu of heat 105.3 kWh
    34 / 100
  • Equipment price $1,795.00
    76 / 100
  • Heat retained at 5°F 79.2%
    23 / 100
  • Seasonal cooling efficiency 24.5 SEER2
    42 / 100
  • Earlier weighted value score 102.9 (size-class reference of 100)
    23 / 100

Electricity per million Btu

Cooling
40.8 kWh
Heating · Region IV rating
105.3 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$188.95
Heat available at 5°F
9,500 Btu/h
COP at 5°F
1.95
Electricity per million Btu at 5°F
150.3 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
N/A

A cooling-mode fan range is unavailable in the model documents.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$1,795
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the VIR12HP115V1R32AH and VIR12HP115V1R32AO, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Budget Heating & Air Conditioning
    $1,795

What an installation quote covers

The median equipment price in the 12,000 Btu/h class is $1,980.95 (29 of 29 systems priced).

Earlier price and efficiency score

Weighted score 102.9. Provisional · Based on one retailer. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 98.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity12,000 Btu/h
Marketed size class12,000 Btu/h
Seasonal efficiency (SEER2)24.5 Btu/Wh
Efficiency at the rating point (EER2)13 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)9.5 Btu/Wh
Rated output at 47°F12,000 Btu/h
Rated output at 17°F10,000 Btu/h
Rated output at 5°F9,500 Btu/h
Sound levels
Indoor minimum · operating mode unspecified20 dB(A)
Installation details
Power supply115 V
RefrigerantR-32
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings26.5%
Cooling input reduction at the EER2 test point7.7%
Seasonal heating electricity savings5.3%
Electricity savings with equal heating and cooling loads12.4%
Heat at 5°F as a share of rated heat at 47°F79.2%
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) referenceN/A

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3544219
AHRI reference214813258
Cold Climate designationYes
Rated cooling12,000 Btu/h
Heating at 47°F12,000 Btu/h
Heating at 17°F10,000 Btu/h
Heating at 5°F9,500 Btu/h
COP at 5°F1.95
SEER224.5 Btu/Wh
EER213 Btu/Wh
HSPF29.5 Btu/Wh
5°F output as a share of 47°F rated output79.17%

Reading the sources

The manufacturer lists both component numbers together in its single-zone equipment submittal.