Mitsubishi Electric WX 18,000 Btu/h class
Mitsubishi Electric rates this single-zone wall system for 17,200 Btu/h of cooling. It uses a 208/230 V supply and R-454B refrigerant.
- Indoor unit
- MSZ-WX18NL
- Outdoor unit
- MUZ-WX18NL
Cost and room performance
Equipment and ten years of electricity
$5,540.38
- Listed equipment price
- $2,422.73 3 retailers
- Ten years of electricity
- $3,117.65
- Annual electricity use
- 1,732.0 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Scores by criterion
Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated
-
10-year equipment + electricity $5,540.3855 / 100
-
Price per 1,000 Btu/h at 5°F N/AN/A / 100
-
Heat available at 5°F N/AN/A / 100
-
Electricity for 1 million Btu at 5°F N/AN/A / 100
-
Minimum heat at 47°F 5,400 Btu/h62 / 100
-
Minimum cooling at 95°F 5,800 Btu/h60 / 100
-
Indoor sound, lowest fan 32 dB(A)28 / 100
-
Indoor sound, highest fan 49 dB(A)36 / 100
-
Electricity for 1 million Btu of cooling 55.6 kWh11 / 100
-
Electricity for 1 million Btu of heat 117.6 kWh13 / 100
-
Equipment price $2,422.7361 / 100
-
Heat retained at 5°F N/AN/A / 100
-
Seasonal cooling efficiency 18 SEER26 / 100
-
Earlier weighted value score 101.8 (size-class reference of 100)21 / 100
Electricity per million Btu
- Cooling
- 55.6 kWh
- Heating · Region IV rating
- 117.6 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- N/A
- Heat available at 5°F
- N/A
- COP at 5°F
- N/A
- Electricity per million Btu at 5°F
- N/A
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 5,400 Btu/h
- Minimum cooling output at 95°F
- 5,800 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 32–49 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment price & installation
- Average equipment price
- $2,422.73
- 3 retailers · $2,242 to $2,654.07 · Price sources reviewed
Prices cover the listed equipment package. Installation, tax and shipping are separate.
What would the whole job cost?
Ask for an estimate for the MSZ-WX18NL and MUZ-WX18NL, including labor, refrigerant lines and electrical work.
Equipment price sources
- AC Units for Less$2,242
- Got Ductless$2,372.11
- HVACDirect$2,654.07
The median equipment price in the 18,000 Btu/h class is $3,099.75 (18 of 18 systems priced).
Earlier price and efficiency score
Weighted score 101.8. The reference for the 18,000 Btu/h class is 100.
Efficiency-only benchmark 84.3.
Published specifications
Cooling
| Rated cooling capacity | 17,200 Btu/h |
|---|---|
| Marketed size class | 18,000 Btu/h |
| Minimum output at 95°F | 5,800 Btu/h |
| Maximum output at 95°F | 18,000 Btu/h |
| Seasonal efficiency (SEER2) | 18 Btu/Wh |
| Efficiency at the rating point (EER2) | 9.5 Btu/Wh |
| Rated power input at 95°F | 1,810 W |
| Moisture removal | 5.2 US pt/h |
| Sensible heat factor | 0.67 |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 8.5 Btu/Wh |
|---|---|
| Rated output at 47°F | 18,000 Btu/h |
| Minimum output at 47°F | 5,400 Btu/h |
| Maximum output at 47°F | 20,800 Btu/h |
| Rated output at 17°F | 11,700 Btu/h |
| Maximum output at 17°F | 15,000 Btu/h |
| COP at 47°F · rated output | 3.14 |
| COP at 17°F · maximum output | 1.74 |
| Power at 47°F · rated output | 1,680 W |
| Power at 17°F · rated output | 1,360 W |
Sound levels
| Indoor, cooling · quietest setting | 32 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 49 dB(A) |
| Indoor cooling fan stages · published order | 32 / 38 / 44 / 49 dB(A) |
| Indoor, heating · quietest setting | 31 dB(A) |
| Indoor, heating · highest published level | 46 dB(A) |
| Indoor heating fan stages · published order | 31 / 36 / 41 / 46 dB(A) |
| Outdoor unit in cooling mode | 53 dB(A) |
| Outdoor unit in heating mode | 51 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-454B |
| Specified breaker size | 20 A |
| Maximum line-set length | 65 ft |
| Maximum vertical separation | 40 ft |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Standard compressor coverage | 7 years |
The linked Mitsubishi Electric residential terms apply to purchases from June 1, 2026. Registration, installer and state rules can affect the term.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 0.0% |
|---|---|
| Cooling input reduction at the EER2 test point | -26.3% |
| Seasonal heating electricity savings | -5.9% |
| Electricity savings with equal heating and cooling loads | -3.9% |
| Heat at 5°F as a share of rated heat at 47°F | N/A |
| Cooling turndown below rated capacity at 95°F | 66.3% |
| Quietest cooling mode below a 30 dB(A) reference | -2 dB(A) |
ENERGY STAR cross-check
The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.