Daikin AURORA Wall-Mount 18,000 Btu/h class

Daikin rates this single-zone wall system for 18,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXV18AVJU9
Outdoor unit
RXT18AVJU9

Cost and room performance

Equipment and ten years of electricity

$6,612.64

Listed equipment price
$3,880.50 2 retailers
Ten years of electricity
$2,732.14
Annual electricity use
1,517.9 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. The 5°F readings come from an ENERGY STAR model-family match. How scores are calculated

  • 10-year equipment + electricity $6,612.64
    34 / 100
  • Price per 1,000 Btu/h at 5°F $179.65
    61 / 100
  • Heat available at 5°F 21,600 Btu/h
    77 / 100
  • Electricity for 1 million Btu at 5°F 162.8 kWh
    8 / 100
  • Minimum heat at 47°F 5,800 Btu/h
    58 / 100
  • Minimum cooling at 95°F 6,900 Btu/h
    50 / 100
  • Indoor sound, lowest fan 33 dB(A)
    22 / 100
  • Indoor sound, highest fan 48 dB(A)
    43 / 100
  • Electricity for 1 million Btu of cooling 47.6 kWh
    37 / 100
  • Electricity for 1 million Btu of heat 104.2 kWh
    36 / 100
  • Equipment price $3,880.50
    27 / 100
  • Heat retained at 5°F 100%
    50 / 100
  • Seasonal cooling efficiency 21 SEER2
    22 / 100
  • Earlier weighted value score 90.9 (size-class reference of 100)
    7 / 100

Electricity per million Btu

Cooling
47.6 kWh
Heating · Region IV rating
104.2 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$179.65
Heat available at 5°F
21,600 Btu/h
COP at 5°F
1.8
Electricity per million Btu at 5°F
162.8 kWh

EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
5,800 Btu/h
Minimum cooling output at 95°F
6,900 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
33–48 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Average equipment price
$3,880.50
2 retailers · $3,660 to $4,101 · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the FTXV18AVJU9 and RXT18AVJU9, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Got Ductless
    $3,660
  • The AC Outlet
    $4,101

What an installation quote covers

The median equipment price in the 18,000 Btu/h class is $3,099.75 (18 of 18 systems priced).

Earlier price and efficiency score

Weighted score 90.9. The reference for the 18,000 Btu/h class is 100.

Efficiency-only benchmark 98.2.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F18,000 Btu/h
Minimum output at 95°F6,900 Btu/h
Maximum output at 95°F22,000 Btu/h
Seasonal efficiency (SEER2)21 Btu/Wh
Efficiency at the rating point (EER2)12 Btu/Wh

The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.

Heating
Seasonal efficiency (HSPF2, Region IV)9.6 Btu/Wh
Rated output at 47°F21,600 Btu/h
Minimum output at 47°F5,800 Btu/h
Maximum output at 47°F28,000 Btu/h
Output at 5°F · load unspecified21,600 Btu/h
COP at 5°F · rated output1.8
Sound levels
Indoor, cooling · quietest setting33 dB(A)
Indoor, cooling · highest published level48 dB(A)
Indoor, heating · quietest setting33 dB(A)
Indoor, heating · highest published level49 dB(A)
Outdoor unit in cooling mode55 dB(A)
Outdoor unit in heating mode57 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Maximum overcurrent protection20 A
Maximum line-set length98.5 ft
Indoor unit weight27 lb
Outdoor unit weight127 lb
Warranty
Standard parts coverage5 years
Extended parts coverage · conditions apply12 years

Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings14.3%
Cooling input reduction at the EER2 test point0.0%
Seasonal heating electricity savings6.2%
Electricity savings with equal heating and cooling loads8.9%
Heat at 5°F as a share of rated heat at 47°F100.0%
Cooling turndown below rated capacity at 95°F61.7%
Quietest cooling mode below a 30 dB(A) reference-3 dB(A)

ENERGY STAR cross-check

The listing covers a model family. ENERGY STAR publishes the outdoor unit as RXT18AVJU* and the indoor unit as FTXV18AVJU*.

ENERGY STAR ID3893675
AHRI reference215389735
Cold Climate designationYes
Rated cooling18,000 Btu/h
Heating at 47°F21,600 Btu/h
Heating at 17°F15,200 Btu/h
Heating at 5°F21,600 Btu/h
COP at 5°F1.8
SEER221 Btu/Wh
EER212 Btu/Wh
HSPF29.6 Btu/Wh
5°F output as a share of 47°F rated output100%

minisplitscout.com/systems/ftxv18avju9--rxt18avju9/