Daikin OTERRA 230V 12,000 Btu/h class

Daikin rates this single-zone wall system for 12,000 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXF12BVJU9
Outdoor unit
RXF12BVJU9

Cost and room performance

Equipment and ten years of electricity

$4,613.60

Listed equipment price
$1,991.75 2 retailers
Ten years of electricity
$2,621.85
Annual electricity use
1,456.6 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $4,613.60
    74 / 100
  • Price per 1,000 Btu/h at 5°F N/A
    N/A
  • Heat available at 5°F N/A
    N/A
  • Electricity for 1 million Btu at 5°F N/A
    N/A
  • Minimum heat at 47°F 4,400 Btu/h
    72 / 100
  • Minimum cooling at 95°F 4,400 Btu/h
    73 / 100
  • Indoor sound, lowest fan 19 dB(A)
    100 / 100
  • Indoor sound, highest fan 46 dB(A)
    57 / 100
  • Electricity for 1 million Btu of cooling 47.6 kWh
    37 / 100
  • Electricity for 1 million Btu of heat 98 kWh
    47 / 100
  • Equipment price $1,991.75
    71 / 100
  • Heat retained at 5°F N/A
    N/A
  • Seasonal cooling efficiency 21 SEER2
    22 / 100
  • Earlier weighted value score 96.3 (size-class reference of 100)
    14 / 100

Electricity per million Btu

Cooling
47.6 kWh
Heating · Region IV rating
98 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
N/A
Heat available at 5°F
N/A
COP at 5°F
N/A
Electricity per million Btu at 5°F
N/A

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
4,400 Btu/h
Minimum cooling output at 95°F
4,400 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
19–46 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Average equipment price
$1,991.75
2 retailers · $1,957 to $2,026.50 · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the FTXF12BVJU9 and RXF12BVJU9, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Got DuctlessThe seller listing was captured about 2 days before the November 24, 2026 review.
    $1,957
  • SupplyHouseThe seller listing was captured on November 24, 2026.
    $2,026.50

What an installation quote covers

The median equipment price in the 12,000 Btu/h class is $1,980.95 (29 of 29 systems priced).

Earlier price and efficiency score

Weighted score 96.3. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 94.2.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity12,000 Btu/h
Marketed size class12,000 Btu/h
Minimum output at 95°F4,400 Btu/h
Maximum output at 95°F14,600 Btu/h
Seasonal efficiency (SEER2)21 Btu/Wh
Efficiency at the rating point (EER2)12.5 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)10.2 Btu/Wh
Rated output at 47°F13,500 Btu/h
Minimum output at 47°F4,400 Btu/h
Maximum output at 47°F18,000 Btu/h
Sound levels
Indoor, cooling · quietest setting19 dB(A)
Indoor, cooling · highest published level46 dB(A)
Indoor, heating · quietest setting25 dB(A)
Indoor, heating · highest published level45 dB(A)
Outdoor unit in cooling mode49 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Specified breaker size15 A
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings14.3%
Cooling input reduction at the EER2 test point4.0%
Seasonal heating electricity savings11.8%
Electricity savings with equal heating and cooling loads12.6%
Heat at 5°F as a share of rated heat at 47°FN/A
Cooling turndown below rated capacity at 95°F63.3%
Quietest cooling mode below a 30 dB(A) reference11 dB(A)

ENERGY STAR cross-check

The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.

Reading the sources

Daikin US shows both model numbers in the same system specification table on PDF page 30.

Indoor sound pressure is the cooling/heating H/M/L/SL fan-speed row on the catalog page. Minima and maxima correspond to SL and H. The pair-specific capacity source specifies 95°F outdoor dry-bulb in cooling and 47°F outdoor dry-bulb in heating, with rated, minimum and maximum capacities. Outdoor cooling 49 dBA is from EDUS042405, PDF page 9; catalog p30 has a single 48-dBA value for the outdoor unit.