Daikin ENTRA 12,000 Btu/h class
Daikin rates this single-zone wall system for 11,600 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- FTXC12BVJU9
- Outdoor unit
- RXC12BVJU9
Cost and room performance
Equipment and ten years of electricity
$4,649.63
- Listed equipment price
- $1,531.98 2 retailers
- Ten years of electricity
- $3,117.65
- Annual electricity use
- 1,732.0 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Scores by criterion
Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated
-
10-year equipment + electricity $4,649.6373 / 100
-
Price per 1,000 Btu/h at 5°F N/AN/A / 100
-
Heat available at 5°F N/AN/A / 100
-
Electricity for 1 million Btu at 5°F N/AN/A / 100
-
Minimum heat at 47°F 3,000 Btu/h85 / 100
-
Minimum cooling at 95°F 3,000 Btu/h85 / 100
-
Indoor sound, lowest fan 21 dB(A)89 / 100
-
Indoor sound, highest fan 46 dB(A)57 / 100
-
Electricity for 1 million Btu of cooling 55.6 kWh11 / 100
-
Electricity for 1 million Btu of heat 117.6 kWh13 / 100
-
Equipment price $1,531.9882 / 100
-
Heat retained at 5°F N/AN/A / 100
-
Seasonal cooling efficiency 18 SEER26 / 100
-
Earlier weighted value score 97.8 (size-class reference of 100)16 / 100
Electricity per million Btu
- Cooling
- 55.6 kWh
- Heating · Region IV rating
- 117.6 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- N/A
- Heat available at 5°F
- N/A
- COP at 5°F
- N/A
- Electricity per million Btu at 5°F
- N/A
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 3,000 Btu/h
- Minimum cooling output at 95°F
- 3,000 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 21–46 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment price & installation
- Average equipment price
- $1,531.98
- 2 retailers · $1,499 to $1,564.96 · Price sources reviewed
Prices cover the listed equipment package. Installation, tax and shipping are separate.
What would the whole job cost?
Ask for an estimate for the FTXC12BVJU9 and RXC12BVJU9, including labor, refrigerant lines and electrical work.
Equipment price sources
- AC Units For LessThe retailer listed this system on backorder. The seller listing was captured about a month before the November 24, 2026 review.$1,499
- HVAC PlaceThe seller listing was captured about a month before the November 24, 2026 review.$1,564.96
The median equipment price in the 12,000 Btu/h class is $1,980.95 (29 of 29 systems priced).
Earlier price and efficiency score
Weighted score 97.8. The reference for the 12,000 Btu/h class is 100.
Efficiency-only benchmark 76.7.
Published specifications
Cooling
| Rated cooling capacity | 11,600 Btu/h |
|---|---|
| Marketed size class | 12,000 Btu/h |
| Minimum output at 95°F | 3,000 Btu/h |
| Seasonal efficiency (SEER2) | 18 Btu/Wh |
| Efficiency at the rating point (EER2) | 8.4 Btu/Wh |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 8.5 Btu/Wh |
|---|---|
| Rated output at 47°F | 11,300 Btu/h |
| Minimum output at 47°F | 3,000 Btu/h |
Sound levels
| Indoor, cooling · quietest setting | 21 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 46 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-32 |
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 0.0% |
|---|---|
| Cooling input reduction at the EER2 test point | -42.9% |
| Seasonal heating electricity savings | -5.9% |
| Electricity savings with equal heating and cooling loads | -3.9% |
| Heat at 5°F as a share of rated heat at 47°F | N/A |
| Cooling turndown below rated capacity at 95°F | 74.1% |
| Quietest cooling mode below a 30 dB(A) reference | 9 dB(A) |
ENERGY STAR cross-check
The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.
Reading the sources
Daikin US shows both model numbers in the same system specification table on PDF page 10. The engineering manual, PDF page 7, gives rated output and mode-specific sound pressure.