Fujitsu AIRSTAGE Altair 500 30,000 Btu/h class

Fujitsu rates this single-zone wall system for 30,000 Btu/h of cooling. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
ASUH30KPAS
Outdoor unit
AOUH30KPAS1

Cost and room performance

Equipment and ten years of electricity

$6,589.59

Listed equipment price
$4,006.70 single retailer
Ten years of electricity
$2,582.89
Annual electricity use
1,434.9 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $6,589.59
    34 / 100
  • Price per 1,000 Btu/h at 5°F $155.30
    73 / 100
  • Heat available at 5°F 25,800 Btu/h
    100 / 100
  • Electricity for 1 million Btu at 5°F 133.2 kWh
    62 / 100
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan 32 dB(A)
    28 / 100
  • Indoor sound, highest fan 51 dB(A)
    21 / 100
  • Electricity for 1 million Btu of cooling 45.5 kWh
    44 / 100
  • Electricity for 1 million Btu of heat 98 kWh
    47 / 100
  • Equipment price $4,006.70
    24 / 100
  • Heat retained at 5°F 86%
    32 / 100
  • Seasonal cooling efficiency 22 SEER2
    28 / 100
  • Earlier weighted value score 109 (size-class reference of 100)
    31 / 100

Electricity per million Btu

Cooling
45.5 kWh
Heating · Region IV rating
98 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$155.30
Heat available at 5°F
25,800 Btu/h
COP at 5°F
2.2
Electricity per million Btu at 5°F
133.2 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
32–51 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$4,006.70
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the ASUH30KPAS and AOUH30KPAS1, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • Got DuctlessBoth exact units in a single available US heat-pump system listing; price for the default equipment variant.
    $4,006.70

What an installation quote covers

The median equipment price in the 30,000 Btu/h class is $4,006.70 (3 of 3 systems priced).

Earlier price and efficiency score

Weighted score 109. Provisional · Based on one retailer. The reference for the 30,000 Btu/h class is 100.

Efficiency-only benchmark 115.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity30,000 Btu/h
Marketed size class30,000 Btu/h
Published minimum · outdoor temperature unspecified9,900 Btu/h
Published maximum · outdoor temperature unspecified32,400 Btu/h
Seasonal efficiency (SEER2)22 Btu/Wh
Efficiency at the rating point (EER2)11.7 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)10.2 Btu/Wh
Rated output at 47°F30,000 Btu/h
Rated output at 17°F19,600 Btu/h
Published minimum · outdoor temperature unspecified9,200 Btu/h
Published maximum · outdoor temperature unspecified34,800 Btu/h
Sound levels
Indoor, cooling · quietest setting32 dB(A)
Indoor, cooling · highest published level51 dB(A)
Outdoor unit in cooling mode53 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Specified breaker size30 A
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings18.2%
Cooling input reduction at the EER2 test point-2.6%
Seasonal heating electricity savings11.8%
Electricity savings with equal heating and cooling loads13.9%
Heat at 5°F as a share of rated heat at 47°F86.0%
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) reference-2 dB(A)

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3629536
AHRI reference215390440
Cold Climate designationYes
Rated cooling30,000 Btu/h
Heating at 47°F30,000 Btu/h
Heating at 17°F19,600 Btu/h
Heating at 5°F25,800 Btu/h
COP at 5°F2.2
SEER222 Btu/Wh
EER211.7 Btu/Wh
HSPF210.2 Btu/Wh
5°F output as a share of 47°F rated output86%

Reading the sources

Manufacturer's US wall-mounted single-room series page lists this exact outdoor unit in the indoor model's Compatible Outdoor Units entry.

Source page explicitly names these two model numbers. Catalog cooling/heating modulation ranges are reported without an outdoor test temperature. Keep them separate from minimum-at-95°F/47°F metrics. The 47°F and 17°F heating capacities, where provided, come from the linked exact ENERGY STAR record.

minisplitscout.com/systems/asuh30kpas--aouh30kpas1/