Fujitsu AIRSTAGE Altair 300 9,000 Btu/h class

Fujitsu rates this single-zone wall system for 9,000 Btu/h of cooling. It uses a 115 V supply and R-32 refrigerant.

Indoor unit
ASLH09KNAS
Outdoor unit
AOLH09KNAS1

Cost and room performance

Equipment and ten years of electricity

$4,345.40

Listed equipment price
$1,286.58 2 retailers
Ten years of electricity
$3,058.82
Annual electricity use
1,699.3 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $4,345.40
    79 / 100
  • Price per 1,000 Btu/h at 5°F N/A
    N/A
  • Heat available at 5°F N/A
    N/A
  • Electricity for 1 million Btu at 5°F N/A
    N/A
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan 20 dB(A)
    94 / 100
  • Indoor sound, highest fan 41 dB(A)
    93 / 100
  • Electricity for 1 million Btu of cooling 58.8 kWh
    0 / 100
  • Electricity for 1 million Btu of heat 111.1 kWh
    24 / 100
  • Equipment price $1,286.58
    87 / 100
  • Heat retained at 5°F N/A
    N/A
  • Seasonal cooling efficiency 17 SEER2
    0 / 100
  • Earlier weighted value score 103.9 (size-class reference of 100)
    24 / 100

Electricity per million Btu

Cooling
58.8 kWh
Heating · Region IV rating
111.1 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
N/A
Heat available at 5°F
N/A
COP at 5°F
N/A
Electricity per million Btu at 5°F
N/A

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
20–41 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment price & installation

Average equipment price
$1,286.58
2 retailers · $1,229 to $1,344.15 · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the ASLH09KNAS and AOLH09KNAS1, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • AirConditionersRUsSingle-system price on the exact matched-pair product page. Seller marks this item special order.
    $1,229
  • Got DuctlessBoth exact units in a single available US heat-pump system listing; price for the default equipment variant.
    $1,344.15

What an installation quote covers

The median equipment price in the 9,000 Btu/h class is $1,876.44 (26 of 26 systems priced).

Earlier price and efficiency score

Weighted score 103.9. The reference for the 9,000 Btu/h class is 100.

Efficiency-only benchmark 76.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity9,000 Btu/h
Marketed size class9,000 Btu/h
Published minimum · outdoor temperature unspecified3,100 Btu/h
Published maximum · outdoor temperature unspecified10,500 Btu/h
Seasonal efficiency (SEER2)17 Btu/Wh
Efficiency at the rating point (EER2)10.55 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)9 Btu/Wh
Published minimum · outdoor temperature unspecified3,100 Btu/h
Published maximum · outdoor temperature unspecified12,400 Btu/h
Sound levels
Indoor, cooling · quietest setting20 dB(A)
Indoor, cooling · highest published level41 dB(A)
Outdoor unit in cooling mode45 dB(A)
Installation details
Power supply115 V
RefrigerantR-32
Specified breaker size20 A
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings-5.9%
Cooling input reduction at the EER2 test point-13.7%
Seasonal heating electricity savings0.0%
Electricity savings with equal heating and cooling loads-2.0%
Heat at 5°F as a share of rated heat at 47°FN/A
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) reference10 dB(A)

ENERGY STAR cross-check

The U.S. heat-pump list reviewed on contained no verified record for this pair. The model sheet uses the linked equipment documents.

Reading the sources

Manufacturer's US wall-mounted single-room series page lists this exact outdoor unit in the indoor model's Compatible Outdoor Units entry.

Source page explicitly names these two model numbers. Catalog cooling/heating modulation ranges are reported without an outdoor test temperature. Keep them separate from minimum-at-95°F/47°F metrics.

minisplitscout.com/systems/aslh09knas--aolh09knas1/