Samsung WindFree Max Heat 24,000 Btu/h class
Samsung rates this single-zone wall system for 22,000 Btu/h of cooling. It uses a 208–230 V supply and R-32 refrigerant.
- Indoor unit
- AR24DXDABWKNCV
- Outdoor unit
- AR24DXDACWKXCV
- U.S. indoor code
- RNX24ABD
- U.S. outdoor code
- RXX24ACD
Cost and room performance
Equipment and ten years of electricity
$6,203.74
- Listed equipment price
- $3,409 single retailer
- Ten years of electricity
- $2,794.74
- Annual electricity use
- 1,552.6 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Scores by criterion
Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated
-
10-year equipment + electricity $6,203.7442 / 100
-
Price per 1,000 Btu/h at 5°F N/AN/A / 100
-
Heat available at 5°F N/AN/A / 100
-
Electricity for 1 million Btu at 5°F N/AN/A / 100
-
Minimum heat at 47°F N/AN/A / 100
-
Minimum cooling at 95°F N/AN/A / 100
-
Indoor sound, lowest fan N/AN/A / 100
-
Indoor sound, highest fan N/AN/A / 100
-
Electricity for 1 million Btu of cooling 50 kWh29 / 100
-
Electricity for 1 million Btu of heat 105.3 kWh34 / 100
-
Equipment price $3,409.0038 / 100
-
Heat retained at 5°F N/AN/A / 100
-
Seasonal cooling efficiency 20 SEER217 / 100
-
Earlier weighted value score 98.2 (size-class reference of 100)17 / 100
Electricity per million Btu
- Cooling
- 50 kWh
- Heating · Region IV rating
- 105.3 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- N/A
- Heat available at 5°F
- N/A
- COP at 5°F
- N/A
- Electricity per million Btu at 5°F
- N/A
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- N/A
- Minimum cooling output at 95°F
- N/A
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- N/A
A cooling-mode fan range is unavailable in the model documents.
Equipment price & installation
- Single retailer price
- $3,409
- 1 retailer · Price sources reviewed
Prices cover the listed equipment package. Installation, tax and shipping are separate.
What would the whole job cost?
Ask for an estimate for the AR24DXDABWKNCV and AR24DXDACWKXCV, including labor, refrigerant lines and electrical work.
Equipment price sources
- HVAC PlaceOne listed price for the exact paired indoor and outdoor equipment SKUs. Excludes shipping, tax and installation. The seller listing was captured about 2 months before the November 24, 2026 review.$3,409
The median equipment price in the 24,000 Btu/h class is $3,299 (15 of 15 systems priced).
Earlier price and efficiency score
Weighted score 98.2. Provisional · Based on one retailer. The reference for the 24,000 Btu/h class is 100.
Efficiency-only benchmark 99.1.
Published specifications
Cooling
| Rated cooling capacity | 22,000 Btu/h |
|---|---|
| Marketed size class | 24,000 Btu/h |
| Published minimum · outdoor temperature unspecified | 8,500 Btu/h |
| Published maximum · outdoor temperature unspecified | 31,000 Btu/h |
| Seasonal efficiency (SEER2) | 20 Btu/Wh |
| Efficiency at the rating point (EER2) | 12.8 Btu/Wh |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 9.5 Btu/Wh |
|---|---|
| Nominal heating output in the manufacturer catalog | 25,000 Btu/h |
| Published minimum · outdoor temperature unspecified | 7,500 Btu/h |
| Published maximum · outdoor temperature unspecified | 42,500 Btu/h |
Sound levels
| Indoor fan settings · operating mode unspecified | 47 / 28 dB(A) |
|---|
Installation details
| Power supply | 208–230 V |
|---|---|
| Refrigerant | R-32 |
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 10.0% |
|---|---|
| Cooling input reduction at the EER2 test point | 6.2% |
| Seasonal heating electricity savings | 5.3% |
| Electricity savings with equal heating and cooling loads | 6.8% |
| Heat at 5°F as a share of rated heat at 47°F | N/A |
| Cooling turndown below rated capacity at 95°F | N/A |
| Quietest cooling mode below a 30 dB(A) reference | N/A |
ENERGY STAR cross-check
The U.S. ENERGY STAR records below omit the CV suffix on both model numbers. Winter rankings on this site require a verified pair or an explicit EPA model-family match.
Reading the sources
Indoor and outdoor model names appear in the same column of the North American technical data book. Refrigerant follows the model-specific system table.