Samsung WindFree Standard 15,000 Btu/h class

Samsung rates this single-zone wall system for 15,000 Btu/h of cooling. It uses a 208–230 V supply and R-32 refrigerant.

Indoor unit
AR15DXFAMWKNCV
Outdoor unit
AR15DXFAMWKXCV
U.S. indoor code
RNX15AMD
U.S. outdoor code
RXX15AMD

Cost and room performance

Equipment and ten years of electricity

$4,296.21

Listed equipment price
$1,659 single retailer
Ten years of electricity
$2,637.21
Annual electricity use
1,465.1 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $4,296.21
    80 / 100
  • Price per 1,000 Btu/h at 5°F N/A
    N/A
  • Heat available at 5°F N/A
    N/A
  • Electricity for 1 million Btu at 5°F N/A
    N/A
  • Minimum heat at 47°F N/A
    N/A
  • Minimum cooling at 95°F N/A
    N/A
  • Indoor sound, lowest fan N/A
    N/A
  • Indoor sound, highest fan N/A
    N/A
  • Electricity for 1 million Btu of cooling 46.5 kWh
    41 / 100
  • Electricity for 1 million Btu of heat 100 kWh
    44 / 100
  • Equipment price $1,659.00
    79 / 100
  • Heat retained at 5°F N/A
    N/A
  • Seasonal cooling efficiency 21.5 SEER2
    25 / 100
  • Earlier weighted value score 136.1 (size-class reference of 100)
    66 / 100

Electricity per million Btu

Cooling
46.5 kWh
Heating · Region IV rating
100 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
N/A
Heat available at 5°F
N/A
COP at 5°F
N/A
Electricity per million Btu at 5°F
N/A

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
N/A
Minimum cooling output at 95°F
N/A

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
N/A

A cooling-mode fan range is unavailable in the model documents.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$1,659
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the AR15DXFAMWKNCV and AR15DXFAMWKXCV, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • HVAC PlaceOne listed price for the exact paired indoor and outdoor equipment SKUs. Excludes shipping, tax and installation. The seller listing was captured about a week before the November 24, 2026 review.
    $1,659

What an installation quote covers

The median equipment price in the 15,000 Btu/h class is $3,293.23 (8 of 8 systems priced).

Earlier price and efficiency score

Weighted score 136.1. Provisional · Based on one retailer. The reference for the 15,000 Btu/h class is 100.

Efficiency-only benchmark 94.4.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity15,000 Btu/h
Marketed size class15,000 Btu/h
Published minimum · outdoor temperature unspecified5,500 Btu/h
Published maximum · outdoor temperature unspecified20,000 Btu/h
Seasonal efficiency (SEER2)21.5 Btu/Wh
Efficiency at the rating point (EER2)12.95 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)10 Btu/Wh
Nominal heating output in the manufacturer catalog15,000 Btu/h
Published minimum · outdoor temperature unspecified4,000 Btu/h
Published maximum · outdoor temperature unspecified26,000 Btu/h
Sound levels
Indoor fan settings · operating mode unspecified41 / 27 dB(A)
Installation details
Power supply208–230 V
RefrigerantR-32
Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings16.3%
Cooling input reduction at the EER2 test point7.3%
Seasonal heating electricity savings10.0%
Electricity savings with equal heating and cooling loads12.1%
Heat at 5°F as a share of rated heat at 47°FN/A
Cooling turndown below rated capacity at 95°FN/A
Quietest cooling mode below a 30 dB(A) referenceN/A

ENERGY STAR cross-check

The U.S. ENERGY STAR records below omit the CV suffix on both model numbers. Winter rankings on this site require a verified pair or an explicit EPA model-family match.

Reading the sources

Indoor and outdoor model names appear in the same column of the North American technical data book. Refrigerant follows the model-specific system table.

minisplitscout.com/systems/ar15dxfamwkncv--ar15dxfamwkxcv/