ACiQ Platinum Extreme Heat 6,000 Btu/h class

ACiQ rates this single-zone wall system for 6,000 Btu/h of cooling. It uses a 208/230 V supply and R-454B refrigerant.

Indoor unit
ACIQ-06W-HH-MD
Outdoor unit
ACIQ-06ZPL-HP230C

Cost and room performance

Equipment and ten years of electricity

$3,322.10

Listed equipment price
$1,400 single retailer
Ten years of electricity
$1,922.10
Annual electricity use
1,067.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Scores by criterion

Scores compare systems on each criterion. The best measured result earns 100 and the worst earns 0. N/A means a reading or score is unavailable. How scores are calculated

  • 10-year equipment + electricity $3,322.10
    100 / 100
  • Price per 1,000 Btu/h at 5°F $181.82
    60 / 100
  • Heat available at 5°F 7,700 Btu/h
    2 / 100
  • Electricity for 1 million Btu at 5°F 122.6 kWh
    81 / 100
  • Minimum heat at 47°F 3,000 Btu/h
    85 / 100
  • Minimum cooling at 95°F 2,300 Btu/h
    91 / 100
  • Indoor sound, lowest fan N/A
    N/A
  • Indoor sound, highest fan N/A
    N/A
  • Electricity for 1 million Btu of cooling 39.2 kWh
    65 / 100
  • Electricity for 1 million Btu of heat 67.6 kWh
    100 / 100
  • Equipment price $1,400.00
    85 / 100
  • Heat retained at 5°F 110%
    62 / 100
  • Seasonal cooling efficiency 25.5 SEER2
    47 / 100
  • Earlier weighted value score 111.4 (size-class reference of 100)
    34 / 100

Electricity per million Btu

Cooling
39.2 kWh
Heating · Region IV rating
67.6 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$181.82
Heat available at 5°F
7,700 Btu/h
COP at 5°F
2.39
Electricity per million Btu at 5°F
122.6 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
3,000 Btu/h
Minimum cooling output at 95°F
2,300 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
N/A

ACiQ reports indoor sound by fan speed without identifying the operating mode.

Formulas and ranking rules

Equipment price & installation

Single retailer price
$1,400
1 retailer · Price sources reviewed

Prices cover the listed equipment package. Installation, tax and shipping are separate.

What would the whole job cost?

Ask for an estimate for the ACIQ-06W-HH-MD and ACIQ-06ZPL-HP230C, including labor, refrigerant lines and electrical work.

Call for an installation quote(833) 246-4401
Equipment price sources
  • HVACDirectIndoor unit $400 + outdoor unit $1,000
    $1,400

What an installation quote covers

The median equipment price in the 6,000 Btu/h class is $1,677.50 (3 of 3 systems priced).

Earlier price and efficiency score

Weighted score 111.4. Provisional · Based on one retailer. The reference for the 6,000 Btu/h class is 100.

Efficiency-only benchmark 105.8.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity6,000 Btu/h
Minimum output at 95°F2,300 Btu/h
Maximum output at 95°F12,600 Btu/h
Seasonal efficiency (SEER2)25.5 Btu/Wh
Efficiency at the rating point (EER2)18 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)14.8 Btu/Wh
Rated output at 47°F7,000 Btu/h
Minimum output at 47°F3,000 Btu/h
Maximum output at 47°F11,000 Btu/h
Rated output at 17°F7,900 Btu/h
Rated output at 5°F7,700 Btu/h
Maximum output at 5°F7,700 Btu/h
COP at 5°F · rated output2.39
Sound levels
Indoor minimum · operating mode unspecified19.5 dB(A)
Indoor maximum · operating mode unspecified44 dB(A)
Outdoor · operating mode unspecified53 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-454B
Minimum circuit ampacity12 A
Maximum overcurrent protection15 A
System product code810175551678
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years
Extended parts coverage · conditions apply7 years
Extended compressor coverage · conditions apply12 years

The extended term applies to the original registrant after a qualifying residential installation is registered within 90 days. See the warranty for the applicable start date.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings29.4%
Cooling input reduction at the EER2 test point33.3%
Seasonal heating electricity savings39.2%
Electricity savings with equal heating and cooling loads35.9%
Heat at 5°F as a share of rated heat at 47°F110.0%
Cooling turndown below rated capacity at 95°F61.7%
Quietest cooling mode below a 30 dB(A) referenceN/A

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3723314
AHRI reference216032333
Cold Climate designationYes
Rated cooling6,000 Btu/h
Heating at 47°F7,000 Btu/h
Heating at 17°F8,700 Btu/h
Heating at 5°F7,700 Btu/h
COP at 5°F2.39
SEER225.5 Btu/Wh
EER218 Btu/Wh
HSPF214.8 Btu/Wh
5°F output as a share of 47°F rated output110%

Reading the sources

ACiQ lists indoor sound by fan speed without identifying the operating mode. These levels stay separate from the cooling-only comparison.